Red Top vs. SST Blood Collection Tubes: A U.S. Purchasing Guide
Summary
- For routine serum testing in the United States, most laboratories purchase either red-top tubes without gel or serum separator tubes (SSTs) containing Clot Activator and polymer gel.
- The correct tube depends on the test method, specimen volume, laboratory validation, centrifugation requirements, and whether special handling is needed for trace elements, therapeutic drugs, hormones, or infectious-disease testing.
- Purchasers should evaluate tube additives, material, size, expiration date, lot traceability, regulatory documentation, storage conditions, total cost, and compatibility with the laboratory’s analyzers and collection procedures.
Choosing the right blood collection tube is one of the most important purchasing decisions in phlebotomy and clinical laboratory operations. A tube that appears appropriate based only on color may still be unsuitable for a specific laboratory test. Tube additives, Separator Gel, tube material, specimen volume, Clotting Time, centrifugation settings, transport conditions, and analyzer compatibility can all affect the accuracy and stability of a serum sample.
In the United States, routine serum collection generally involves two major tube categories: red-top tubes and serum separator tubes, commonly called SSTs. Red-top tubes are typically used when the laboratory wants serum without Separator Gel. SSTs contain a Clot Activator and a polymer gel that forms a barrier between the serum and the clot after centrifugation. Both products are widely used, but they are not interchangeable for every test.
Purchasing decisions should be based on the laboratory’s test menu and written specimen requirements rather than on tube color alone. The Clinical and Laboratory Standards Institute, or CLSI, provides widely used guidance for venous blood collection and specimen handling, including recommendations concerning the order of draw, tube filling, clotting, centrifugation, and transport. Laboratories should also consider applicable U.S. Food and Drug Administration requirements, Occupational Safety and Health Administration requirements, accreditation standards, and manufacturer instructions for use.
What Is a Serum Collection Tube?
Serum is the liquid portion of blood that remains after the blood has clotted and the cells and clot have been removed. Unlike plasma, serum does not contain fibrinogen in its normal form because clotting consumes or converts important coagulation proteins. Serum is used for a broad range of chemistry, immunology, serology, endocrinology, Toxicology, Therapeutic Drug Monitoring, and specialized laboratory tests.
A serum tube generally contains no anticoagulant. The blood is allowed to clot, and the tube is then centrifuged. Some serum tubes contain a Clot Activator to shorten the time required for clot formation. Other tubes contain a gel separator that moves during centrifugation and creates a physical barrier between the serum and the cellular clot.
The most important purchasing distinction is therefore not simply the tube’s cap color. The buyer should determine whether the tube contains:
- No additive, as commonly found in a plain red-top tube.
- A Clot Activator, which promotes or accelerates clot formation.
- A Clot Activator and Separator Gel, as found in many SSTs.
- A specialized surface treatment or additive intended for a particular test category.
Tube colors are industry conventions, but color shades can vary by manufacturer and product line. A gold-top tube from one supplier may not have exactly the same additive or gel formulation as a gold-top tube from another supplier. The product label, package insert, catalog description, and laboratory validation records should always take priority over color assumptions.
The Two Main Options for Routine Serum Collection
Red-top tubes
Red-top tubes are designed to produce serum without a gel barrier. Depending on the product, they may be made of glass or plastic and may be completely plain or contain a Clot Activator. Plain glass tubes naturally promote clotting because glass contacts the blood. Plastic red-top tubes may require a Clot Activator to provide comparable clotting performance.
Red-top tubes can be useful when a laboratory wants direct access to the serum without Separator Gel. They may also be preferred for certain reference laboratory tests, specialized assays, blood bank-related procedures, or methods known to be affected by gel contact. Because there is no barrier, the serum usually must be transferred to another tube if prolonged storage or transport could allow continued contact between serum and cells.
When purchasing red-top tubes, ask the supplier whether the product is plain or contains Clot Activator. This difference matters. A plain tube and a clot-activator tube should not be treated as identical products unless the laboratory has confirmed that both provide acceptable results for the intended assays.
Serum separator tubes
Serum separator tubes are among the most commonly purchased tubes for routine clinical chemistry and immunology testing in the United States. They generally contain a Clot Activator and a polymer gel. After the sample clots and is centrifuged, the gel moves between the serum and the cellular clot, creating a separator barrier.
SSTs can improve Workflow by reducing the need to manually transfer serum into a secondary tube. They are particularly convenient for high-volume outpatient collection, hospital laboratories, physician offices, urgent care centers, and reference laboratory shipments. The gel barrier may also reduce cellular contamination during transport and storage.
However, SSTs are not automatically suitable for every analyte. Some drugs, hormones, trace elements, and other compounds may interact with the gel or tube material. Some laboratories also avoid gel tubes for tests requiring serum to be separated immediately or for assays with specific manufacturer restrictions. The laboratory should review the test directory and analyzer instructions before standardizing on an SST.
When Should You Purchase Red-Top Tubes?
Red-top tubes may be the better purchase when the laboratory has one or more of the following requirements:
- The test manufacturer specifies serum collected without Separator Gel.
- The laboratory performs assays that may be affected by gel contact or gel-related adsorption.
- The specimen must be transferred to a dedicated transport or aliquot tube after clotting.
- The laboratory uses a reference method or specialized procedure validated with plain serum tubes.
- The test requires a serum specimen with a particular collection surface or tube material.
- The laboratory wants flexibility for manual processing and does not need a gel barrier.
Glass red-top tubes may be selected for particular applications because glass can promote clotting without an added activator. However, glass is heavier and more breakable than plastic. It may increase shipping weight and handling risk, especially in Mobile Phlebotomy, home collection, long-distance courier transport, and high-volume outpatient environments.
Plastic red-top tubes are lighter and less likely to break, but the laboratory must verify clotting performance. A plastic tube with Clot Activator may provide more predictable clot formation than a plain plastic tube. If clotting is incomplete, fibrin strands can interfere with analyzer probes, cause instrument flags, or produce rejected specimens.
When Should You Purchase SSTs?
SSTs are usually a strong choice for routine serum chemistry, liver function testing, renal function testing, lipid testing, many hormone assays, immunoassays, serology procedures, and general outpatient blood collection. They are also convenient when the laboratory wants a barrier between serum and cells during short-term transport.
The main advantages of SSTs include:
- Reduced need for manual serum transfer.
- Improved separation of serum from cells after centrifugation.
- Potentially simpler specimen processing in high-volume laboratories.
- Lower exposure to open specimens during aliquoting.
- Convenient handling for courier transport when the tube has been properly centrifuged and stored.
The principal limitation is that the gel is not chemically neutral for every laboratory application. Some analytes may be absorbed into the gel, released from the gel, or affected by prolonged contact with the gel. These effects depend on the analyte, gel composition, storage conditions, temperature, and time. A tube approved for general chemistry should not automatically be assumed to be suitable for every specialized test.
Laboratories that use SSTs should also follow the manufacturer’s instructions for clotting and centrifugation. Many products require the tube to remain upright while the blood clots, commonly for approximately 30 minutes. The exact time can vary by product and patient condition. Premature centrifugation may produce fibrin, microclots, or an unstable barrier.
Understanding Tube Additives and Materials
Clot Activator
Clot activators are designed to accelerate or promote coagulation. They may be present as a dry coating or another formulation applied to the tube interior. Clot Activator tubes are not Anticoagulant tubes and should not be mixed with tubes intended for plasma collection.
Although clot activators are intended to improve consistency, individual patients may clot at different rates. Patients receiving Anticoagulant medications, patients with Clotting Disorders, and patients with difficult collections may require additional attention. A tube that appears full may still contain an inadequate clot if the sample is centrifuged too soon.
Separator Gel
Separator Gel is a thixotropic material that changes behavior under centrifugation. When the tube is spun at the correct speed and duration, the gel moves to form a barrier based on the density difference between serum and the clot. The barrier can protect serum from direct contact with cells, but it is not a substitute for timely processing.
Buyers should verify the gel’s intended use, centrifugation requirements, acceptable storage temperatures, and stability claims. If the laboratory uses multiple centrifuges, it should confirm that each centrifuge can meet the product’s required relative centrifugal force, or RCF. Revolutions per minute alone are not sufficient for comparing centrifuge performance because RCF also depends on rotor radius.
Glass and plastic
Glass tubes offer a rigid collection surface and may be preferred for certain procedures. Their disadvantages include breakage risk, additional weight, and possible workplace handling concerns. Plastic tubes are lighter and generally safer for transport, but their additive and surface characteristics may differ from glass products.
In the United States, many healthcare facilities have shifted toward plastic collection systems to reduce breakage and improve workplace safety. Nevertheless, the decision should be based on validated test performance rather than a general preference for one material.
Tube Size and Required Blood Volume
Common serum tube sizes include approximately 3.5 mL, 4 mL, 5 mL, 6 mL, 7 mL, 8.5 mL, and 10 mL, although available sizes vary by manufacturer. The correct size depends on the requested tests, the laboratory’s minimum volume requirements, dead volume, repeat testing needs, and whether the specimen must be divided among multiple departments.
Purchasing oversized tubes for every collection can increase patient discomfort, product cost, storage requirements, and blood loss. This is particularly important for pediatric patients, older adults, Oncology Patients, and patients undergoing repeated testing. At the same time, purchasing tubes that are too small may lead to insufficient volume, cancelled tests, or additional recollection.
Vacuum tubes are designed to draw a particular volume. If the tube is underfilled, the tube’s internal vacuum may be reduced or the volume may not meet the laboratory’s validated requirements. Underfilling is especially important for additive tubes, but serum tubes also need adequate volume for the requested test and analyzer dead-volume requirements.
Before placing a large order, compare the laboratory’s test volume data with its current tube consumption. A basic purchasing review should examine the number of serum specimens collected each month, the average number of tubes used per patient, rejected specimen rates, recollection rates, pediatric volume requirements, and the percentage of tubes that expire before use.
Special Serum Collection Situations
Trace-element and Toxicology testing
Trace-element testing may require tubes manufactured with specially controlled materials. Ordinary serum tubes can introduce contamination from metals or other substances. For tests involving lead, mercury, aluminum, copper, zinc, selenium, or other trace elements, the laboratory should purchase only the tube type specified by the performing laboratory or assay manufacturer.
Royal-blue-top tubes are often associated with trace-element testing, but their additive and intended specimen type can differ. Some royal-blue tubes are designed for serum, while others contain anticoagulants for plasma or whole blood. The cap color alone is not enough to select the product.
Therapeutic Drug Monitoring
Drug levels may be affected by tube material, Clot Activator, Separator Gel, adsorption, timing of collection, and specimen stability. For medications with narrow therapeutic ranges, a tube that is acceptable for routine chemistry may not be appropriate for drug monitoring. The laboratory should verify the exact tube requirements for drugs such as anticonvulsants, immunosuppressants, antibiotics, and certain psychiatric medications.
Hormones and specialized immunoassays
Many hormone and immunology tests can be performed on serum collected in SSTs, but special requirements are common. Some assays require serum free of gel, while others require a defined minimum volume or rapid separation. If a laboratory sends specialized tests to a reference laboratory, the reference laboratory’s specimen directory should govern purchasing.
Microbiology and infectious-disease testing
Serum used for serology and infectious-disease testing may be collected in red-top or SST products, depending on the assay. The correct tube may vary even within the same clinical category. For example, one antibody test may accept serum from an SST, while another may require a plain tube or a specific minimum volume. Purchasing teams should maintain a test-to-tube matrix for all commonly ordered assays.
U.S. Regulatory and Quality Considerations
Blood collection tubes used in the United States are medical devices subject to FDA oversight. Buyers should confirm that the product is legally marketed for its intended use and that the supplier can provide appropriate labeling, instructions for use, lot information, and quality documentation. Depending on the device and manufacturer, documentation may include clearance information, declarations, certificates, or other regulatory records.
OSHA’s Bloodborne Pathogens Standard requires employers to use appropriate engineering and work-practice controls to reduce occupational exposure to blood. Although a serum tube is only one part of the collection system, purchasing decisions should consider whether the tube is compatible with the organization’s safety needles, holders, transfer devices, transport bags, and sharps disposal procedures.
Clinical laboratories accredited by organizations such as the College of American Pathologists, The Joint Commission, or other accrediting bodies generally need documented procedures for specimen collection, identification, processing, storage, transport, and Quality Control. A new tube brand or product should be evaluated through the laboratory’s change-control process before routine use.
CLSI guidance is widely used to support standardized blood collection practices. The order of draw, tube mixing, clotting, centrifugation, and specimen handling should be consistent with current laboratory policy and the applicable tube manufacturer’s instructions. The laboratory should also monitor preanalytical quality indicators. Published laboratory quality studies often report that preanalytical problems account for roughly 46% to 68% of identified laboratory errors, although the exact percentage varies by study design and setting.
What to Ask a Supplier Before Purchasing
Price is important, but it should not be the only purchasing criterion. A low unit price can be offset by recollection costs, rejected specimens, Workflow delays, instrument problems, and expired inventory. Ask the supplier for clear answers to the following questions:
- Is the tube plain, clot-activator, gel separator, or a combination product?
- Is the tube intended for serum, plasma, whole blood, or more than one specimen type?
- What is the nominal draw volume and acceptable fill range?
- What are the required Clotting Time and centrifugation conditions?
- Is the product made of glass or plastic?
- Which analytes or test categories have been validated by the manufacturer?
- What are the product’s storage temperature and humidity requirements?
- What is the typical shelf life at the time of shipment?
- Can the supplier provide lot traceability and certificates of analysis when required?
- Is the product compatible with the laboratory’s existing holders, centrifuges, racks, automation, and analyzers?
- What is the supplier’s policy for damaged, short-dated, recalled, or incorrectly shipped products?
- Can the supplier maintain continuity of supply during shortages or manufacturing changes?
Purchasers should avoid accepting substitutions based solely on identical cap colors. Any substitute should be reviewed by the laboratory director, quality manager, or designated technical authority. A change in tube manufacturer can alter clotting behavior, gel position, tube dimensions, barcode readability, or analyzer performance.
Calculating the Total Cost of Serum Tubes
The invoice price is only one component of total cost. A more useful purchasing model includes the tube, storage, shipping, waste, processing labor, recollection, rejected testing, and inventory carrying costs.
For example, an SST may cost more per tube than a plain red-top tube, but it may reduce manual aliquoting and lower the number of open-tube handling steps. Conversely, an SST may be a poor value if the laboratory’s test menu requires frequent serum transfer or if gel-related restrictions lead to repeat collections.
Inventory management is also important. Many healthcare facilities maintain several weeks or months of collection supplies, but excessive inventory creates expiration risk. A practical approach is to establish minimum and maximum stock levels based on average monthly use, supplier lead time, emergency reserve requirements, and known seasonal changes in collection volume.
When comparing vendors, calculate the cost per usable specimen rather than cost per tube. A product with a slightly higher purchase price may have a lower cost per usable specimen if it produces fewer rejected samples and requires less processing time.
Validation Before Full-Scale Adoption
Before converting an entire facility to a new serum tube, the laboratory should conduct a documented evaluation. The scope depends on the intended use, but common elements include comparison of patient specimens collected in the current and proposed tubes, assessment of clotting, gel barrier formation, hemolysis, fibrin, sample volume, analyzer flags, and result agreement.
For quantitative assays, the laboratory may compare paired specimens across clinically relevant concentrations. The number of samples and statistical approach should be determined by the laboratory director and quality program. Specialized tests may require additional review by the performing reference laboratory.
Validation should also examine real-world Workflow. Test the tube with the actual needle and holder system, centrifuge, racks, pneumatic tube system if used, transport packaging, barcode labels, and analyzer. A tube that performs well on a bench may create problems in automation or transport.
Document the product name, catalog number, manufacturer, lot number, tube additive, draw volume, test applications, acceptance criteria, approval date, and responsible reviewer. Retain manufacturer instructions and records of the evaluation according to the facility’s document-control policy.
Common Purchasing Mistakes to Avoid
- Choosing tubes by cap color without reviewing the additive and intended specimen type.
- Assuming every gold-top tube is interchangeable with every other gold-top tube.
- Purchasing gel tubes for tests that specifically require plain serum.
- Ignoring pediatric and low-volume collection requirements.
- Failing to check the remaining shelf life before accepting a shipment.
- Changing tube brands without laboratory validation.
- Using a tube beyond its expiration date or outside its specified storage conditions.
- Neglecting the effect of tube dimensions on centrifuge cups, racks, and automated systems.
- Underestimating the importance of complete clotting before centrifugation.
- Ordering large quantities before confirming supply continuity and lot consistency.
A Practical Recommendation for Most U.S. Facilities
For a general U.S. outpatient or hospital laboratory performing routine serum chemistry and immunology testing, a validated SST with Clot Activator and Separator Gel is often the most practical primary purchase. A facility should generally select a standard size that meets its routine volume requirements, frequently a 4 mL to 6 mL format, while maintaining smaller options for pediatric and low-volume collections.
A plain red-top tube should usually remain available as a secondary product for tests that require serum without gel, reference laboratory requirements, specialized assays, or situations in which the laboratory needs to transfer serum. The exact product should be selected after reviewing the facility’s test directory.
Specialty tubes, including trace-element tubes and tubes for specific drug or molecular applications, should be purchased separately and used only for validated tests. A comprehensive test-to-tube chart should identify the required tube type, minimum volume, Clotting Time, centrifugation instructions, storage temperature, transport limitations, and rejection criteria.
Final Purchasing Checklist
Before issuing a purchase order, confirm the following:
- The tube additive matches the intended serum testing applications.
- The tube size provides sufficient specimen volume without unnecessary blood loss.
- The tube has been validated with the laboratory’s instruments and procedures.
- The supplier provides current instructions for use and regulatory documentation.
- The product has sufficient remaining shelf life at delivery.
- The packaging protects tubes from breakage, contamination, and environmental damage.
- The product is compatible with existing needles, holders, centrifuges, racks, labels, and automation.
- The facility has a documented procedure for clotting, centrifugation, storage, transport, and rejection.
- There is a contingency plan for shortages, recalls, backorders, and manufacturer changes.
- The laboratory director or other qualified technical authority has approved the final selection.
In summary, routine serum collection in the United States most often calls for either a red-top tube or an SST, but the best choice depends on the specific testing environment. SSTs are convenient for many routine applications because they combine clot activation with a gel barrier. Red-top tubes remain important when a laboratory requires serum without gel or performs tests with special specimen restrictions. The safest purchasing strategy is to combine current laboratory guidance, manufacturer instructions, regulatory requirements, test-specific validation, and careful inventory analysis rather than relying on tube color or price alone.
Disclaimer: The content provided on this blog is for informational purposes only, reflecting the personal opinions and insights of the author(s) on the topics. The information provided should not be used for diagnosing or treating a health problem or disease, and those seeking personal medical advice should consult with a licensed physician. Always seek the advice of your doctor or other qualified health provider regarding a medical condition. Never disregard professional medical advice or delay in seeking it because of something you have read on this website. If you think you may have a medical emergency, call 911 or go to the nearest emergency room immediately. No physician-patient relationship is created by this web site or its use. No contributors to this web site make any representations, express or implied, with respect to the information provided herein or to its use. While we strive to share accurate and up-to-date information, we cannot guarantee the completeness, reliability, or accuracy of the content. The blog may also include links to external websites and resources for the convenience of our readers. Please note that linking to other sites does not imply endorsement of their content, practices, or services by us. Readers should use their discretion and judgment while exploring any external links and resources mentioned on this blog.